Description
Applications
- Especially suited for occasional short-duration overpressures of up to 4 times scale range
- Increased safety requirements
- With liquid filled case for applications with high dynamic pressure pulsations or vibrations (Model 233.36)
- For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive ambience
- Process industries: chemical/petro-chemical, power stations, mining, on- and offshore, environmental technology, mechanical engineering and plant construction
Special Features
- High overpressure safety, overpressure range is indicated completely on scale
- Safety pressure gauge with solid baffle wall designed in compliance with operational safety requirements of EN 837-1
- All stainless steel construction
Description
Design
Safety pattern (Solidfront) referring to EN 837-1
Nominal size
100 and 160 mm
Measuring range (bar) Overpressure range up to … bar
-1 … 0 3
0 … 0,6 2,5
0 … 1 4
0 … 1,6 6
0 … 2,5 10
0 … 4 16
0 … 6 25
0 … 10 40
0 … 16 60
0 … 25 80
0 … 40 100
Accuracy class
Measuring range: 1.0
The measuring range end is marked by a triangle
Pressure limitation
Steady: end value of measuring range
Fluctuating: 0.9 x end value of measuring range
Short time: Overpressure range
Permissible temperature
Ambient:
-40 … +60°C without liquid filling
-20 … +60 °C gauges with glycerine filling (Model 233.36 )
Medium:
+200 °C maximum without liquid filling
+100 °C maximum with liquid filling (Model 233.36 )
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 % / 10 K of full scale value
Ingress protection
IP 65 per EN 60529/IEC 529